Comparison of Tc-99m pertechnetate images with dual-phase Tc 99m MIBI and SPECT images in primary hyperparathyroidism


1 Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey
2 Department of Endocrine Surgery, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey

Date of Web Publication25-Jul-2014

Correspondence Address:
Sait Sager
Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Cerrahpasa, Fatih, Istanbul
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2230-8210.137520

Rights and Permissions
   Abstract 

Background: The purpose of this study was to evaluate the value of Tc-99m pertechnetate planar, dual-phase MIBI and MIBI-SPECT images in the determination and localization of parathyroid lesions. Materials and Methods: In this study, 38 patients who underwent operation for primary hyperparathyroidism were included. Tc-99m pertechnetate planar-pinhole imaging of the neck and then MIBI planar and SPECT images in supine position was performed. Late SPECT images were acquired 120 minutes after the injection. Early and late MIBI images were quantitatively evaluated. Results: Of the 38 patients, 30 of them had adenoma, 2 patients had hyperplasia and 6 of them were normal on planar images. Thirty-four of 38 patients were positive on SPECT images. SPECT images of the patients with positive results were matched with pathology results. Conclusion: As a result, Tc-99m pertechnetate planar-pinhole, Tc-99m MIBI planar and SPECT images are useful for localization of parathyroid lesions especially in multinodular thyroid gland. However, US or CT images are necessary for more accurate localization and Tc-99m pertechnetate images are useful for interpreting and comparing with the early and late MIBI images.

Keywords: MIBI, primary hyperparathyroidism, scintigraphy, Single-photon emission computed tomography, TC-99m pertechnetate


How to cite this article:
Sager S, Shafipour H, Asa S, Yilmaz S, Teksoz S, Onsel C. Comparison of Tc-99m pertechnetate images with dual-phase Tc 99m MIBI and SPECT images in primary hyperparathyroidism. Indian J Endocr Metab 2014;18:531-6

How to cite this URL:
Sager S, Shafipour H, Asa S, Yilmaz S, Teksoz S, Onsel C. Comparison of Tc-99m pertechnetate images with dual-phase Tc 99m MIBI and SPECT images in primary hyperparathyroidism. Indian J Endocr Metab [serial online] 2014 [cited 2019 Nov 22];18:531-6. Available from: http://www.ijem.in/text.asp?2014/18/4/531/137520


   Introduction Top


Primary hyperparathyroidism (PHP) is an endocrine system disease, mostly seen in older population. [1] The cause of PHP is solitary parathyroid adenoma (PA) in 80-85% of the cases. Number of imaging techniques have been used for preoperative localization of parathyroid adenoma including Technetium-99m labelled methoxyisobutyl isonitrile (Tc-99m-MIBI), ultrasound (US), magnetic resonance imaging (MRI) and computed tomography (CT). However these imaging methods have low sensitivity in PA localization. Although some authors use US alone as the primary modality to diagnose parathyroid adenoma and hyperplasia, it is dependent on the physician's experience and has a suboptimal detection rate in multinodular goiter, also in the mediastinum, tracheoesophageal groove and retroesophageal regions. [2],[3],[4] Tc-99m-MIBI is a widely used and accurate scintigraphy technique for the preoperative localization of PA in PHP. Sensitivity of PA diagnosis is improved with early and late planar imaging. Single-photon emission computed tomography (SPECT) imaging provides information about localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, detecting and localizing ectopic parathyroid tissues. [5],[6]

The aim of this study was to compare the value of Tc-99m pertechnetate, dual-phase MIBI and MIBI-SPECT images in the determination and localization of parathyroid lesions and was to compare both planar and SPECT images with lesion based.


   Materials and Methods Top


Ninety-tree patients who referred to parathyroid scintigraphy with the preliminary diagnosis of hyperparathyroidism were included in this study. After positive parathyroid lesion imaging and clinical findings, 38 of these patients were operated. The mean PTH level was 258 ± 161.5 pg/mL, calcium level was 11.26 ± 0.85 mg/dL and phosphor level was 2.56 ± 0.71 mEq/L. For all patients, BUN and creatinine values were in normal limits.

Two patients had history of surgery due to parathyroid adenoma and imaging was performed for recurrent hyperparathyroidism. All patients had thyroid-parathyroid ultrasonography (US).

Imaging

Single head gamma camera was used for planar imaging and dual head gamma camera (Mediso Nucline Spirit, Hungary) was used for SPECT imaging. Twenty minutes after the intravenous injection of 185 MBq Tc-99m pertechnetate, planar imaging and directly after, SPECT imaging of the neck with dual head gamma camera was performed for all patients. Then 20 min after the injection of 740-925 MBq Tc-99m MIBI, 10 minutes of thyroid static images and anterior mediastinum were performed. After planar imaging, MIBI SPECT images were performed with the same parameters as early and late imaging. Late mediastinal images were acquired for 5 min. Late SPECT images were obtained 120 min after the injection of the radiotracer.

Image interpretation

Tc-99m pertechnetate and MIBI, early and late MIBI SPECT images of all patients were interpreted by two independent physicians who were blinded to clinical and other data. Tc-99m pertechnetate images and Tc-99m MIBI images were evaluated together. The relatively increased activity in MIBI images but not be seen in pertechnetate images were considered as pathological parathyroid tissue. Tc-99m pertechnetate planar and SPECT images were used to determine the boundaries of thyroid gland and discriminate the parathyroid gland from thyroid tissue.

Quantitative assessment

For quantitative assessment, region of interest (ROI) was drawn on each Tc-99m MIBI early and late SPECT images according to color scale where the highest level of activity and on the background in every patient. The average number of the count taken from late SPECT images were divided to the average number of the count from early SPECT images.


   Results Top


[Table 1] shows the clinical characteristics of all patients. Out of 38 patients, 30 of them were diagnosed to have PA, 2 patients had PH on planar images, whereas 6 patients were evaluated as normal with planar images [Figure 1]. According to Tc-99m MIBI SPECT images, 34 of 38 patients were diagnosed to have PA. According to both SPECT and planar images, 4 of these 38 patients were observed to have harmonious activities under both thyroid lobes related with PH. Histopathologic evaluation of the lesions which were surgically removed from the same areas confirmed diagnosis of PH.
Figure 1: Tc-99m PO4, Tc-99m MIBI early and late planar images of 38-year-old female patient

Click here to view


Six patients were diagnosed as normal via Tc-99m MIBI and pertechnetate planar images and four of these patients reported to have positive status for parathyroid adenoma in early MIBI SPECT. Thyroid USG revealed MNG in four of these six patient and the other two patients were diagnosed to have solitary NG. Out of these thirty-eight patients, 16 were diagnosed with MNG and 12 of them with solitary NG. According to planar MIBI images, out of these 38 patients, 30 had positive in terms of PA, 2 had PH, whereas 6 had negative. Early MIBI SPECT images of these 34 patients were positive in terms of PA.

Early MIBI SPECT imaging findings matched with pathology results in 34 patients as PA. In one patient, even though scintigraphy showed to have PA at lower right lobe, PA was found to be on the middle right lobe in the surgical operation. According to pathology results, 34 of the 38 patients were diagnosed to have PA and 4 patients were diagnosed to have PH.
Table 1: Characteristics and results of 38 patients


Click here to view


For the other PA cases, early SPECT and planar images correctly determined the lesions. In one patient, Tc-99m pertechnetate scintigraphy showed two thyroid nodules, one of them was large and hyperactive whereas the other one was small and normoactive. Tc-99m MIBI images confirmed the same results. Thyroidectomy was applied to the patient and the pathology result showed multicentric thyroid papillary carcinoma. According to these results, the sensitivity of Tc-99m MIBI planar and pinhole imaging is 88.2%, Tc-99m MIBI SPECT sensitivity is 100% in detecting parathyroid adenoma [Figure 2].
Figure 2: Tc-99m MIBI SPECT images of another patient showed increased uptake in the right inferior adjacent area of the thyroid gland

Click here to view



   Discussion Top


Dual-phase Tc-99m MIBI parathyroid scintigraphy is a valuable method based on the differential washout rate between the thyroid tissue and PA. PAs have very high metabolic rate despite of their small size and they show intense Tc-99m MIBI uptake. Oxyphilic cells which are enriched by mitochondria and the increased vascularity are the main causes of this uptake. [7]

Bilateral exploration of the parathyroid glands with excision of the abnormally enlarged glands and biopsy of at least one normal size gland has been the traditional standard approach for the surgical management of PHP. [8] Experienced endocrine surgeons successfully cure the PHP by bilateral neck dissection in 95% of patients without needing any preoperative imaging. However, the morbidity and unsuccessful surgery rate increase with the less experienced surgeons.

Benard F et al. hypothesized that mitochondria-rich oxyphil cells constitute a logical target for the prolonged retention of Tc-MIBI usually observed in abnormal parathyroids because tissues with a low mitochondrial content would not be expected to significantly accumulate the tracer. In such cases, rapid washout of Tc-99m MIBI from abnormal tissue with low number of mitochondria can result a false negative study on late images. Pathologic parathyroid tissue activity can be observed at early MIBI images probably because of increased flow or cellularity in the tumor. [9] SPECT images are useful for localization of preoperative parathyroid adenomas, which have negative planar imaging and especially for the cases localized in mediastinum and may increase the sensitivity. As already stated in our study, early SPECT have extra contribution to the patients that have been diagnosed with parathyroid adenoma via planar imaging. [10]

To improve the lesion detectability, some studies using a pinhole collimator for imaging reported better localization of adenomas than images acquired by a parallel-hole collimator or delayed SPECT. [11] It is also reported that a combination of early and delayed pinhole imaging and SPECT maximize parathyroid lesion detection. [12] Pinhole SPECT was shown to be a complementary to planar scintigraphy, especially in secondary hyperparathyroidism. [13],[14] Using US combination with scintigraphy is common method for lesion localization and to exclude thyroid nodules in the thyroid glands. Using a hybrid SPECT/CT scan can further enhance localization by providing better resolution of surrounding structures and this system allows for the combined anatomic information from CT and the physiologic three-dimensional information from SPECT. However SPECT/CT is high cost modality and many departments can-not afford this system. Also CT scan gives more radiation to the patients.

The sensitivity of Tc-99m MIBI for localization of preoperative parathyroid adenoma was found different in various studies. Civelek et al. found that the sensitivity of Tc-99m MIBI late SPECT imaging in abnormal parathyroid tissue detection in the patients who had not underwent surgery as 87%, in the patients who had been operated is 92%; and in patients with hyperplasic glands is 45%. [15] Perez-Monte et al. compared the early and late Tc-99m MIBI SPECT images of 37 patients who had parathyroid adenoma and had been operated. Pathologic reports confirmed parathyroid adenoma in 34 patients (92%) and PA in 3 patients (8%). 91% of patients were detected and localized correctly with early SPECT images. 74% of parathyroid adenoma were detected by late SPECT images and 32% of adenoma were correctly localized in this study. [16] Early Tc-99m MIBI SPECT imaging was found better than late Tc-99m MIBI imaging for localization of parathyroid adenomas according to these researchers. [15],[16] The reason of this rapid washout rate of MIBI from adenomas in late images increases the false negativity. Another study comparing the early and late SPECT images of 52 patients found that 41 parathyroid adenoma (79%) were detected by planar imaging and 50 were (96%) by early SPECT imaging. This study showed that SPECT imaging is superior than planar imaging in PA localization especially in patients with ectopic adenomas and multinodular goiter disease. [17] A study with 82 PHP patients, published by Pinhas et al. reported that the sensitivity of planar imaging for parathyroid adenoma was 78% and early SPECT was 96% for parathyroid adenoma localization detection. [18] In our study, early MIBI SPECT correctly found PA localization in 34 out of 38 patients, MIBI planar images found PA localization in 30 out of 38 patients. Also the washout rate of the MIBI was calculated to be 0.686 in quantitative evaluation which had been performed with early and late images of PA adenomas.

On the other hand, there are some authors reporting that SPECT does not bring additional information and does not improve the detection rate for adenomas. Chen et al. found that the sensitivity of Tc-99 MIBI imaging for PA detection was 95%, the sensitivity of late planar imaging is 98% and the late SPECT imaging of Tc-99 MIBI was 98% in 55 hyperparathyroid patients. They conclude that the latter images subtraction images and SPECT images does not necessarily bring much information other than early images with Tc-99m pertechnetate. [19] Staudenherz et al. performed planar images with Tc-99m-MIBI, SPECT, US, and subtraction scintigraphy with Tl-201 and Tc99m-pertechnetate on patients with thyroid disease (50% of the cases) and previous cervical surgery (21% of the cases) and compared the images with the histopathology of the surgical specimen. They found that SPECT provide additional information about adenoma localization in 39% of patients with thyroid disease or previous cervical surgery. However, overall detection rates did not increase. [20]

Some researchers do not advice parathyroid scintigraphy for MNG patients with parathyroid adenomas. Although MNG lowers sensitivity of planar imaging, it does not affect SPECT imaging. However in recent years, SPECT/CT technology gives more information about this kind of MNG patients. In many centers such as our department, US is being used for excluding thyroid nodules. The reason for that is that localization of parathyroid adenomas are more commonly behind thyroid gland. In MNG patients, it is hard to differentiate thyroid nodules from parathyroid nodules if thyroid nodule is MIBI avid. Even though oblique imaging is advised when parathyroid adenomas and thyroid nodules are crossed with each other, it is not useful for parathyroid adenomas. We found that early SPECT is superior to the planar imaging in MNG patients in concordance with the other studies. It is also suggested that in persistent hyperparathyroidism, the accuracy of Tc-99m MIBI SPECT for identification of residual hyperactive glands is considerably lower before reoperation than before initial surgery. [21] In addition, hipervitaminosis D are more likely to cause false positive results on a sestamibi scan. [22]

This study showed that early MIBI SPECT imaging is superior than both planar Tc-99m pertechnetate and planar MIBI scintigraphy in PA localization, especially in MNG patients. Since this protocol takes long time, early MIBI SPECT should be performed only if the MIBI planar imaging is negative or suspicious. Our study demonstrated that quantitative statistics of early and late SPECT imaging is necessary.

As a result, our present study suggest an important additive contribution of the SPECT study not only in localization of the parathyroid adenoma but also in the differentiation between a suspect thyroid nodule and a parathyroid gland localization when SPECT/CT is not achieved or US is not performed.

 
   References Top

1.Palmer M, Jakoobsson S, Akerstrom G, Ljunghall S. Prevalence of hypercalcemia in a health survey: A 14-year follow-up study of serum calcium values. Eur J Clin Invest 1988;18:39-46.  Back to cited text no. 1
    
2.Levy JM, Kandil E, Yau LC, Cuda JD, Sheth SN, Tufano RP. Can ultrasound be used as the primary screening modality for the localization of parathyroid disease prior to surgery for primary hyperparathyroidism? A review of 440 cases. ORL J Otorhinolaryngol Relat Spec 2011;73:116-20.  Back to cited text no. 2
    
3.Lloyd MN, Lees WR, Milroy EJ. Pre-operative localisation in primary hyperparathyroidism. Clin Radiol 1990;41:239-43.  Back to cited text no. 3
    
4.Ahuja AT, Wong KT, Ching AS, Fung MK, Lau JY, Yuen EH, et al. Imaging for primary hyperparathyroidism- what beginners should know. Clin Radiol 2004;59:967-76.  Back to cited text no. 4
    
5.Moka D, Voth E, Dietlein M, Larrrena-Avellannneda A, Schicha H. Technetium 99m-MIBI-SPECT: A highly sensitive diagnostic tool for Localization of Parathyroid adenomas. Surgery 2000;128:29-35.  Back to cited text no. 5
    
6.HoShon IA, Yan W, Roach PJ, Bernard EJ, Shields M, Sywak M, et al. Comparison of pin hole and SPECT Tc-99m-MIBI imaging in primary hyperparathyroidism. Nucl Med Commun 2008;29:949-55.  Back to cited text no. 6
    
7.Sarikaya A, Huseyinova G, Irfanoglu ME, Erkmen N, Cermik TF, Berkarda S. The relationship between 99Tc (m)-sestamibi uptake and ultrastructural cell types of thyroid tumours. Nucl Med Commun 2001;22:39-44.  Back to cited text no. 7
    
8.Boggs JE, Irvin GL, Carneiro DM, Molinari AS. The evolution of parathyroidectomy failures. Surgery 1999;126:998-1002.  Back to cited text no. 8
    
9.Benard F, LeFebre B, Beuvon F, Langlois MF, Bisson G. Parathyroid scintigraphy: Rapid washout of technetium 99m MIBI from a large parathyroid adenoma. J Nucl Med 1995;34:241-3.  Back to cited text no. 9
    
10.Thomas DL, Bartel T, Menda Y, Howe J, Graham MM, Juweid ME. Single photonemission computed tomography (SPECT) should be routinely performed for thedetection of parathyroid abnormalities utilizing technetium-99m sestamibiparathyroid scintigraphy. Clin Nucl Med 2009;34:651-5.  Back to cited text no. 10
    
11.Ho Shon IA, Bernard EJ, Roach PJ, Delbridge LW. The value of oblique pinhole images in pre-operative localization with Tc-99m-MIBI for primary hyperparathyroidism. Eur J Nucl Med 2001;28:736-42.  Back to cited text no. 11
    
12.Nichols KJ, Tomas MB, Tronco GG, Rini JN, Kunjummen BD, Heller KS, et al. Preoperative parathyroid scintigraphic lesion localization: Accuracy of various types of readings. Radiology 2008;248:221-32.  Back to cited text no. 12
    
13.Spanu A, Falchi A, Manca A, Marongiu P, Cossu A, Pisu N, et al. The usefulness of neck pinhole SPECT as a complementary tool to planar scintigraphy in primary and secondary hyperparathyroidism. J Nucl Med 2004;45:40-8.  Back to cited text no. 13
    
14.Arveschoug AK, Bertelsen H, Vammen B. Presurgical localization of abnormal parathyroid glands using a single injection of Tc-99m sestamibi: comparison of high-resolution parallel-hole and pinhole collimators, and interobserver and intraobserver. Clin Nucl Med 2002;27:249-54.  Back to cited text no. 14
    
15.Civelek AC, Ozalp E, Donovan P, Udelsman R. Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localization of primarhy perparathyroidism. Surgery 2002;131:149-57.  Back to cited text no. 15
    
16.Perez-Monte JE, Brown ML, Shah AN, Ranger NT, Watson CG, Carty SE, et al. Parathyroid adenomas: Accurate detection and localization with Tc-99m sestamibiSpect. Radiololgy 1996;201:85-91.  Back to cited text no. 16
    
17.Nichols KJ, Tomas MB, Tronco GG, Rini JN, Kunjummen BD, Heller KS, et al. Preoperative parathyroid scintigraphic lesion localization: Accuracyof various types of readings. Radiology 2008;248:221-32.  Back to cited text no. 17
    
18.Schachter PP, Issa N, Shimonov M, Czerniak A, Lorberboym M. Early, postinjection MIBI-SPECT as the only preoperative localizing study for minimally invasive parathyroidectomy. Arch Surg 2004;139:433-7.  Back to cited text no. 18
    
19.Chen CC, Holder LE, Scovill WA, Tehan AM, Gann DS. Comparison of parathyroid imaging with technetium-99m-pertechnetate/sestamibi subtraction, double-phase technetium-99m-sestamibi and technetium-99m-sestamibi SPECT. J Nucl Med 1997;38:834-9.  Back to cited text no. 19
    
20.Staudenherz A, Abela C, Niederle B, Steiner E, Helbich T, Puig S, et al. Comparison and histopathological correlation of three parathyroid imaging methods in a population with a high prevalence of concomitant thyroid diseases. Eur J Nucl Med 1997;24:143-9.  Back to cited text no. 20
    
21.Witteveen JE, Kievit J, Stokkel MP, Morreau H, Romijn JA, Hamdy NA. Limitations of Tc99m-MIBI-SPECT imaging scans in persistent primary hyperparathyroidism. World J Surg 2010;35:128-39.  Back to cited text no. 21
    
22.Kandil E, Tufaro AP, Carson KA, Lin F, Somervell H, Farrag T, et al. Correlation of plasma 25-hydroxyvitamin D levels with severity of primary hyperparathyroidism and likelihood of parathyroid adenoma localization on sestamibi scan. Arch Otolaryngol Head Neck Surg 2008;134:1071-5.  Back to cited text no. 22
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1059    
    Printed12    
    Emailed0    
    PDF Downloaded282    
    Comments [Add]    

Recommend this journal